Sensors: Rain Gauge
Contents
Rain Gauge
Tipping Bucket Rain Gauge
These have a bucket with two compartments that tips when one fills up which dumps the full bucket, starts filling the other bucket. As the bucket tips, a magnet swings by a magnetic read switch and briefly closes the contacts. The switch is connected between ground and one of the Pi GPIO line XXX. The PIGPIOD daemon/library monitors this GPIO line.
Models
Rainwise
http://www.misolie.net/misol-spare-part-for-weather-station-to-measure-the-rain-volume-for-rain-meter-for-rain-gauge-p-513.html <http://www.misolie.net/misol-spare-part-for-weather-station-to-measure-the-rain-volume-for-rain-meter-for-rain-gauge-p-513.html>
Wiring
Properly terminated RJ11 cable connect the rain gauge to the Yellow and Red wires.
Yellow Ground
Red GPIO XXX
Connection to the Hive Interface baord
Plug the RJ11 into the proper RJ11 jack on the Hive Interface Board.
This is the default sensor configuration but others are possible. The I2C bus communicates with the TSL2195 lux sensor, the DS3231 RTC and the BME680 Temp/Humidity/Pressure/Gas sensor.
Hive Interface Board Digital Sensor Inputs | |||
---|---|---|---|
Name/Purpose | Interface | Header Pins | Sensors |
Lux | I2C | 3, 5 | TSL2561 TSL2591 BME680 |
Hive Temp RH | GPIO/1-Wire | DHT:13 1-Wire:11 | DHT11 DHT22 DS18B20 |
Ambient Temp RH | GPIO/1-Wire | DHT:15 1-Wire:11 | DHT11 DHT22 DS18B20 |
Rain | GPIO/1-Wire | Rain:22 1-Wire:11 | Tipping bucket rain gage and/orDS18B20 |