Difference between revisions of "Growing Degree Day"

From HiveTool
Jump to: navigation, search
Line 3: Line 3:
  
 
[[File:GDD integral.png|frameless|center|400px]]
 
[[File:GDD integral.png|frameless|center|400px]]
 +
where: <br>
 +
T = current temperature<br>
 +
T<sub>base</sub> = temperature below which plant growth is zero.<br>
  
At temperatures above an upper limit, (T<sub>max</sub>), the plant does not grow any faster.
+
At temperatures above an upper limit, (T<sub>max</sub>), the plant does not grow any faster.
  
 
Each plant species  has  its  own  lower  air  temperature  threshold  and  upper  
 
Each plant species  has  its  own  lower  air  temperature  threshold  and  upper  

Revision as of 13:59, 25 November 2018

Growing Degree Days (GDD), also called Growing Degree Units (GDU) or Heat Units (HU), are based on the observation that within limits, plants grow faster when warm and more slowly when cold. Below a base temperature (Tbase), the plant is dormant and little growth occurs. Plants grow in a cumulative stepwise manner which is strongly influenced by the ambient temperature. Since growth depends on the accumulation of specific quantities of heat, by using Growing Degree Days is possible to predict when events such as bud break should occur during a growing season regardless of differences in temperatures from year to year.

GDD integral.png

where:
T = current temperature
Tbase = temperature below which plant growth is zero.

At temperatures above an upper limit, (Tmax), the plant does not grow any faster.

Each plant species has its own lower air temperature threshold and upper air temperature threshold. This temperature range varies for each plant.

Different methods exist for calculating heat units depending on a) the crop or biological organism of interest and b) the whim or personal preference of the researcher. Growing degree day units are calculated by using the maximum daily air temperature, the minimum daily air temperature and the crop’s lower temperature threshold.


The base temperature is that temperature below which plant growth is zero.

The method most commonly used in the U.S. for determining heat unit accumulation relative to corn phenology is the formula first suggested by the National Oceanic and Atmospheric Administration. The “modified growing degree day formula” calculates daily accumulation of GDD’s as the average daily temperature minus 50° F.


Calculate Growing Degree Day (GDD) for each hive and add to database.


Centigrade
Tbase = 10
Tmax  = 30


SET @gdd_total:=0;
SELECT
  q1.doy,
  q1.gdd,
  round(@gdd_total := @gdd_total + q1.gdd) as gdd_tot
FROM
 (SELECT DAYOFYEAR(DATE_FORMAT(`hive_observation_time_local`, '%Y-%m-%d')) AS doy,
  (least(greatest(max(wx_temp_c),10),30) - least(greatest(min(wx_temp_c),10),30))/2 AS gdd
  from HIVE_DATA 
  where hive_id=10 group by DATE_FORMAT(`hive_observation_time_local`, '%Y-%m-%d') ) AS q1



SELECT hive_id, DAYOFYEAR(DATE_FORMAT(`hive_observation_time_local`, '%Y-%m-%d')) AS doy,
  (least(greatest(max(wx_temp_c),10),30) - least(greatest(min(wx_temp_c),10),30))/2 AS gdd
  from HIVE_DATA group by DATE_FORMAT(`hive_observation_time_local`, '%Y-%m-%d'), hive_id